看了动物肺功能检测分析仪的用户又看了
虚拟号将在 180 秒后失效
使用微信扫码拨号
eSpira FM System肺功能检测系统
eSpira™系统是用于检测与肺功能相关的全部生理数据的大型系统,可对麻醉动物进行一系列成组实验的数据自动分析检测,包括用力肺活量相关数据的测试。广泛应用于COPD、肺间质疾病、肺纤维化等疾病临床前研究。
与人肺功能检测相类似,eSpira™系统提供与人类肺功能指标一致的各种生理指标参数。该系统可用于小鼠、大鼠/豚鼠以及其他大型动物。系统高度自动化并提供丰富的图标供分析研究使用。
多参数肺功能检测系统的主要检测参数:
· 用力呼气量Forced Expiratory Volume (FEV)
· 肺总量 Total Lung Capacity
· 用力肺活量Forced Vital Capacity
· * 大呼气流量Peak Expiratory Flow
· * 大呼气中段流量Maximum Mid Expiratory Flow
· 准静态压力容积曲线Quasistatic Pressure Volume Curves
· 功能残气量FRC
· 阻力/顺应性Resistance/Compliance
· Explanations and more parameters
多参数肺功能检测系统的产品主要特点:
· 适用于各种实验动物:小鼠、大鼠、豚鼠、犬、灵长类动物
· 经典的肺量测定法(spirometry)检测肺功能
· 综合的肺功能分析
· COPD及肺间质疾病研究的必备工具;
· 在数分钟内测定FEV(x)、FEF(x)、FVC、FRC、FEVpef、MMEF等参数;
· 气道阻力和肺顺应性直接生理数据检测;
· 软件自动生成可直接打印的数据报告。
FM 动物肺功能检测分析系统 (Anesthetized) --大鼠肺功能测量,小鼠肺功能测量系统:
FM 动物肺功能检测分析系统提供与人肺功能检测相同的各种指标参数,例如FEV(x)、FEF(x)、FVC、FRC、MMEF、TLC等用力呼吸相关的生理指标;兼具弥散(DLCO)、Single Breath Nitrogen Washout等功能,广泛应用于COPD、肺间质疾病、肺纤维化等疾病临床前研究。
该系统同时也能够检测RC系统的阻力与动态肺顺应性等全部参数,并能检测准静态肺顺应性(用于肺塌陷模型的研究)
eSpira FM System肺功能检测系统/动物肺功能检测分析系统 (eSpira™ Forced Manoeuvers System)
eSpira FM System for Mouse
Spirometry is the most common method for assessing lung function within the clinical environment, with FEV1 (Forced Expiratory Volume in one second), in particular, being the most characterised and utilised tests. Until recently, this method of assessing lung function was precluded within the laboratory, as it involved voluntary manoeuvres. However, the EMMS eSpira? system enables a researcher to perform classical spirometry lung function testing on anaesthetised animals.
Typically, animals are intubated or tracheostomised and cannulated. The animal’s lungs are inflated to a set tracheal pressure, and then exposed to a large negative pressure reservoir. This forces the subject to exhale as quickly as possible and enables the scientist to mimic classical clinical spirometry. Parameters calculated include Forced Expiratory Volume (FEVx), where x is the time in milliseconds, Forced Vital Capacity and maximum mid expiratory flow, which gives an average flow over the middle part of the flow volume curve and is useful for determining mild to moderate airway obstruction.
The graph above illustrates data obtained using the eSpira system in a chronic murine model of asthma. Mice were sensitised with Ovalbumin and challenged on multiple occasions. Control animals were injected with alum only and were administered a saline aerosol. The lung function measurements were performed 24 hours after the last challenge. There was a 49% reduction in Forced Vital Capacity (FVC) and a 46% reduction in Forced Expiratory Volume in 50 milliseconds (FEV50). These data illustrate that the eSpira? system is capable of detecting lung function changes, in a murine asthma model, similar to those observed in the clinical environment.
Parameters Measured Include:
· Forced Expiratory Volume (FEV)
· Total Lung Capacity
· Forced Vital Capacity
· Peak Expiratory Flow
· Maximum Mid Expiratory Flow
· Quasistatic Pressure Volume Curves
· FRC
· Resistance/Compliance
· Explanations and more parameters
Features
· Available for all common species from mouse to primate
· Replicates classical spirometry lung function testing
· Comprehensive lung function analysis
·
Uses
· Acute and Chronic models
· Recovery anaesthesia protocols
请关注玉研仪器的更多相关产品。
如对产品细节和价格感兴趣,敬请来电咨询!
暂无数据!