首页 > 粉体测试设备 > 质谱检测分析仪 >
布鲁克timsTOF™ Pro捕集离子淌度质谱
布鲁克timsTOF™ Pro捕集离子淌度质谱

参考价格

面议

型号

品牌

产地

德国

样本

暂无
布鲁克·道尔顿(Bruker Daltonics)

会员

|

第2年

|

生产商

工商已核实

留言询价
核心参数
产品介绍
创新点
相关方案
相关资料
用户评论
公司动态
问商家
留言询价
×

*留言类型

*留言内容

*联系人

*单位名称

*电子邮箱

*手机号

提交
点击提交代表您同意 《用户服务协议》《隐私协议》

虚拟号将在 180 秒后失效

使用微信扫码拨号

为了保证隐私安全,平台已启用虚拟电话,请放心拨打(暂不支持短信)
×
是否已沟通完成
您还可以选择留下联系电话,等待商家与您联系

需求描述

单位名称

联系人

联系电话

Email

已与商家取得联系
同意发送给商家
产品介绍
创新点
相关方案
相关资料
用户评论
公司动态
问商家

the timsTOF™ Pro Mass Spectrometer Enables the Revolutionary PASEF Method for Next-Generation Proteomics

Unique Trapped Ion Mobility Spectrometry (TIMS) Adds New Dimension for Robust, Faster Proteome Analysis with Higher Sensitivity

Overview

  • Powered by PASEF

Mass spectrometry (MS)-based proteomics has become a powerful technology for the identification and quantification of thousands of proteins. However, the coverage of complete proteomes is still very challenging due to the limited speed, sensitivity and resolution of current mass spectrometers.

The timsTOF Pro uses the Parallel Accumulation Serial Fragmentation (PASEF) acquisition method to provide extremely high speed and sensitivity to reach new depths in shotgun proteomics and phosphoproteomics using low sample amounts.

  • Achieve near 100% duty cycle for shotgun proteomics

A near 100% duty cycle for high sensitivity, high speed shotgun proteomics can now be achieved with the dual TIMS technology. The novel design allows for ions to be accumulated in the front section, while ions in the rear section are simultaneously released depending on their ion mobility. This process is called Parallel Accumulation Serial Fragmentation or PASEF.

  • PASEF digs deeper into the proteome

The timsTOF Pro powered by PASEF offers sequencing speed > 100 Hz without losing sensitivity by synchronizing the quadrupole isolation mass window with the elution time of the specific peptide packages from the TIMS funnel.

  • MaxQuant/Perseus and PEAKS Studio enabled data processing

An open-file data format allows researchers to directly work with the raw data and use industry leading software. MaxQuant has been adapted to manage 4D features in the space spanned by retention time, ion mobility, mass, and signal intensity which benefit the identification and quantification of peptides, proteins, and posttranslational modifications. PEAKS Studio combines de novo sequencingwith tradtional databbase searches and is optimized for processing timsTOF raw data.

Technical Details

  • Outstanding hardware performance

The second generation dual TIMS analyzer is optimized for shotgun proteomics needs. Due to its unique geometry ions are released dependent on their mobility from the second section of the TIMS analyzer while the further incoming ions can be accumulated in parallel in the first part of the TIMS analyzer. With the parallel accumulation technology a duty cycle up to 100% can be achieved resulting in no ion loss.

In the timsTOF Pro an advanced segmented quadrupole mass filter is used for high ion transmission and isolation efficiency. The quadrupole mass position is synchronized with the elution times of the specific ions from the TIMS analyzer. Due to its ultra-high mass position switching time (< 1 ms) it enables the best performance for the PASEF method.

  • TIMS

Trapped Ion Mobility Spectrometry (TIMS) is first and foremost a separation technique in gas phase, which resolves sample complexity with an added dimension of separation in addition to HPLC and mass spectrometry, increasing peak capacity and confidence in compound characterization.

  • PASEF

With speed in mind, Bruker experts redesigned MS/MS technology to meet the requirements of shotgun proteomics. Peptide ions are separated using trapped ion mobility spectrometry, eluted (~ 100 ms) and detected in the QTOF, generating the TIMS MS heat map (A). In the PASEF method (B) the same TIMS separation is used with the quadrupole isolating a certain ion species during its elution and immediately shifting to the next precursor. Parent and fragment spectra are aligned by mobility values. With the Parallel Accumulation Serial Fragmentation (PASEF) Technology >100 Hz sequencing speed can be achieved. With the PASEF method the MS/MS spectra quality of the low abundant peptides can be increased by selecting them several times.

创新点

暂无数据!

相关方案
暂无相关方案。
相关资料
暂无数据。
用户评论

产品质量

10分

售后服务

10分

易用性

10分

性价比

10分
评论内容
暂无评论!
公司动态
暂无数据!
技术文章
暂无数据!
问商家
  • 布鲁克timsTOF™ Pro捕集离子淌度质谱的工作原理介绍?
  • 布鲁克timsTOF™ Pro捕集离子淌度质谱的使用方法?
  • 布鲁克timsTOF™ Pro捕集离子淌度质谱多少钱一台?
  • 布鲁克timsTOF™ Pro捕集离子淌度质谱使用的注意事项
  • 布鲁克timsTOF™ Pro捕集离子淌度质谱的说明书有吗?
  • 布鲁克timsTOF™ Pro捕集离子淌度质谱的操作规程有吗?
  • 布鲁克timsTOF™ Pro捕集离子淌度质谱的报价含票含运费吗?
  • 布鲁克timsTOF™ Pro捕集离子淌度质谱有现货吗?
  • 布鲁克timsTOF™ Pro捕集离子淌度质谱包安装吗?
布鲁克timsTOF™ Pro捕集离子淌度质谱信息由布鲁克·道尔顿(Bruker Daltonics)为您提供,如您想了解更多关于布鲁克timsTOF™ Pro捕集离子淌度质谱报价、型号、参数等信息,欢迎来电或留言咨询。
  • 推荐分类
  • 同类产品
  • 该厂商产品
  • 相关厂商
  • 推荐品牌
免费
咨询
手机站
二维码