Bergoz IPCT DC/AC Current Transducer | Bergoz FCT Current Transformer | Bergoz NPCT | ||
High sensitivity for low current. Differential and net current measurements of multiple conductors. Large internal diameter enables high voltage isolation. | The Fast Current Transformer (FCT) is a wideband AC transformer with a rise time down to 175ps and a bandwidth up to 2GHz. | The New Parametric Current Transformer (NPCT) is a zero-flux DC current transformer. | ||
•Peak Current: ±10mA .. ±5000mA•Resolution: 10uA•Bandwidth: DC – 4.2kHz | •Bandwidth up to 1.75GHz 200-ps risetime•Droop down to 0.1%/μs down to 160 Hz lower cutoff freqency•Extra-high sensitivity up to 5 V/A | •Full scale range from ±20mA to ±20A controlled by TTL levels•5 μA/sqrt(Hz) resolution in every range•1 μA/sqrt(Hz) or lower resolution on option | ||
Bergoz CWCT | Bergoz ACCT | Bergoz ICT, Turbo-ICT, BCM | ||
The CWCT is a current transformer with strict limits on lower and upper cut-off frequencies, tailored to the beam RF. | The ACCT is non-interceptive current transformer. | The Integrating Current Transformer (ICT) is a capacitively shorted transformer and a fast read out transformer in a common magnetic circuit designed to measure the charge in a very short pulse with high accuracy. | ||
•Beam repetition frequency 60~500 MHz•Average current with 1 μA resolution•Fast beam loss interlock 1 μs•Linearity error <1.5%•Beam loss resolution <1 % | •Output current range range from ±10mA to ±2A full scale.•Frequency response from 5Hz to 350kHz•DC current up to 1A does not saturate the sensor•Radiation hard sensors available. | •Integrates a very fast pulse with rise time in the order of picoseconds with no significant loss | ||
Bergoz MX-BPM / LR-BPM | Bergoz S-BPM | Bergoz VWM | ||
The Bergoz Multiplexed Beam Position Monitor (MX-BPM) is an electronics module… | The S-band / L-band Beam Position Monitor (S–BPM) is an electronics module for fast analog processing of beam pickups signals. | The VWM is based on the wire resonant frequency dependence on its tension, itself dependent on its temperature | ||
•On-board microstrip filters that elminate the need for costly tubular filters•GaAs switches to provide superior button to button isolation and low insertion loss•On-board systhesized local oscillator | •Non-interceptive beam position measurement.•Beam charge range > 1000. | •Transverse profile and position monitor•Fixed multi-wire sensor or moving sensor•For beams: Photon from infrared to keV, Electron, proton from keV to GeV and Neutrons |